My Account
|
|
Login
go
Home
Probes
Shop by Mode
Conductive AFM (CAFM)
Contact Mode
Critical Dimension (CD) AFM
Deep Trench (DT)
Electrical Spectroscopy
Electrostatic Force Microscopy (EFM)
Fast Scan
Force Modulation
Force Spectroscopy
HarmoniX
Lateral Force Microscopy (LFM)
Magnetic Force Microscopy (MFM)
NanoIndentation
Nanoscale Thermal Analysis
PeakForce QNM
PeakForce Tapping
PeakForce TUNA
Piezoresponse/ Piezoforce Microscopy (PFM)
ScanAsyst
Scanning Capacitance Mode (SCM)
Scanning Electrochemical Potential Microscopy (SECPM)
Scanning Spreading Resistance Mode (SSRM)
Scanning Tunneling Microscopy (STM)
Surface Potential Microscopy (SPoM)
TappingMode/ Non-Contact
Torsional Resonance (TR)
Tunneling AFM (TUNA)
Shop by Application
Electrical
Electrochemistry
Fluid Imaging
General Topography
Holes/ Trenches
Mechanical Force Curves
Mechanical Property Mapping
Pulling
Ultra Hi-Res
Shop by AFM
BioScope
BioScope Catalyst
Caliber
Dimension (Other)
Dimension FastScan
Dimension Icon
EnviroScope
Innova
Insight
MultiMode
NEOS/ Senterra
Non-Bruker AFM
Vx and UVx
Shop by Sample
Bio Molecules
Cells
Ceramics
Data Storage
Other Hard Samples
Other Soft Sample
Polymers
Semiconductors
AFM Accessories
Shop by AFM
BioScope Catalyst
Bioscope®
Caliber™
Dimension
EnviroScope™
For All AFMs
Innova™
MultiMode®
Shop by Accessory Type
Alignment Stands
Calibration References
Calibration Standards
Condensation Windows
Evaporation Covers
Fluid Cell Kits
Fluid Cells
MFM Tool Kits
Mounting Kits
O-Rings
Petri Dish Clamps
Piezo Guards
Probe Holders
Probe Storage Kits
Replacement Springs
Sample Holders
Splash Guards
Starter Kits
Test Samples
AFM Systems
Upgrades by AFM
BioScope Catalyst Upgrades
Dimension Edge Upgrades
Dimension FastScan Upgrades
Dimension Icon Upgrades
Innova Upgrades
MultiMode Upgrades
Trade-Ins by AFM
BioScope/SZ/II Trade-Ins
D3000/D3100/D5000 Trade-Ins
EnviroScope Trade-Ins
Quote Request
Events
Support
AFM Probe FAQs
Bruker site
NanoScale World
Applications Selector Guide
About Bruker AFM Probes
Contact
Shopping Cart (0)
Home
→ Product
Easy Product
Wizard
Sample
Bio Molecules
Cells
Ceramics
Data Storage
Other Hard Samples
Other Soft Sample
Polymers
Semiconductors
Application
Holes/ Trenches
Electrical
Electrochemistry
Fluid Imaging
Mechanical Force Curves
Mechanical Property Mapping
Pulling
General Topography
Ultra Hi-Res
Mode
Conductive AFM (CAFM)
Contact Mode
Critical Dimension (CD) AFM
Electrical Spectroscopy
Electrostatic Force Microscopy (EFM)
Fast Scan
Force Modulation
Force Spectroscopy
HarmoniX
Lateral Force Microscopy (LFM)
Magnetic Force Microscopy (MFM)
NanoIndentation
TappingMode/ Non-Contact
PeakForce QNM
PeakForce Tapping
PeakForce TUNA
Piezoresponse/ Piezoforce Microscopy (PFM)
ScanAsyst
Scanning Capacitance Mode (SCM)
Scanning Electrochemical Potential Microscopy (SECPM)
Scanning Spreading Resistance Mode (SSRM)
Nanoscale Thermal Analysis
Scanning Tunneling Microscopy (STM)
Surface Potential Microscopy (SPoM)
Torsional Resonance (TR)
Tunneling AFM (TUNA)
Deep Trench (DT)
AFM
BioScope
BioScope Catalyst
Caliber
Dimension (Other)
Dimension Icon
Dimension FastScan
EnviroScope
Innova
Insight
MultiMode
NEOS/ Senterra
Non-Bruker AFM
Vx and UVx
Resonant Frequency:
kHz
± 50kHz
± 100kHz
± 200kHz
Spring Constant:
N/m
± 5 N/m
± 10 N/m
± 15 N/m
Search Products
Clear selection
Featured Products
PFTUNA
PFTUNA probes combine the low spring constant and high sensitivity of a nitride cantilever with a sh
Details | Shop
SCANASYST-FLUID+
Product Description:
ScanAsyst-Fluid+ probes have a sharpened tip ideal for high-resolution imaging in fluid. For an intentionally dull
ScanAsyst
tip for force measurements and extremely delicate samples in fluid, please use model
ScanAsyst-Fluid.
Scan
Asyst ut
ilizes a Bruker pr
oprietar
y method for curve collection and sophisticated algorithms to continuously monitor image quality
, and to automatically make appropriate parameter adjustments. This enables:
- Automatic image optimization for faster, more consistent results, regardless of user skill leve
l
.
- Direct force control at ultra-low forces to p
rotect delicate samples and tips from damage.
- Elimination of cantilever tuning, setpoint adjustment, and
gain optim
ization to make even fluid imaging simple.
For use onl
y on ScanAsyst-enabled Dimension Icon, MultiMode 8
,
and BioScop
e Catalyst AFMs.
See the cantilever orientation diagram here.
All ScanAsyst probes have <2 degrees of cantilever bend
.
Add To Cart
Model
Mount
Pack Size
Price
Pack Quantity
SCANASYST-FLUID+
Unmounted
10
****
Shape
Resonant Freq.
kHz
Spring Const.
N/m
Length
µm
Width
µm
Nom.
Min.
Max.
Nom.
Min.
Max.
Nom.
Min.
Max.
Nom.
Min.
Max.
Triangular
150
100
200
0.7
0.35
1.4
70
65
75
10
5
15
Tip Specification
ScanAsyst Fluid+ probes marry the sharpness of a Silicon tip with the low spring constant and high sensitivity of a Silicon Nitride cantilever, for an unprecedented level of high resolution and force control on samples in fluid.
Geometry:
Rotated (Symmetric)
Tip Height (h):
2.5 - 8.0
µm
Front Angle (FA):
15 ± 2.5
º
Back Angle (BA):
25 ± 2.5
º
Side Angle (SA):
17.5 ± 2.5
º
Tip Radius (Nom):
2
nm
Tip Radius (Max):
12
nm
Tip SetBack (TSB)(Nom):
5
µm
Tip Set Back (TSB)(RNG):
3 - 7
µm
Cantilever Specification
Cantilever Orientation diagram can be found here.
ScanAsyst probes have less than 2deg of cantilever bend.
Material:
Silicon Nitride
Geometry:
Triangular
Cantilevers Number:
1
Cantilever Thickness (Nom):
0.6
µm
Cantilever Thickness (RNG):
0.55 - 0.65
µm
Back Side Coating:
Reflective Gold
Top Layer Back:
45 ± 5 nm of Ti/Au
Optional Product Offerings
SCANASYST-AIR
ScanAsyst utilizes a Bruker proprietary method for...
Details | Shop
SCANASYST-FLUID
ScanAsyst-Fluid probes have an intentionally dull ...
Details | Shop
SCANASYST-AIR-HR
ScanAsyst-Air-HR probes are specifically designed ...
Details | Shop